Product Details:
| Minimum Order Quantity | 1 Piece |
| Material | SS 304 AND SS 316 GR OR AS PER CLIENT REQUIREMENT. |
| Usage/Application | Pharmaceutical Industry |
| Size | AS PER CLIENT REQUIREMENT |
| Shape | Square |
| Door Type | Flush door |
| Product Type | FULL S STEEL 304 AND 316 GR ON REQUEST |
| Brand | HMG |
| Voltage | 230 V & 440 V |
| Frequency | 50 Hz * 60 Hz on request |
| Weight | as per model / size |
| Phase | 1 ph as well 3 phase |
| Surface Finishing | SS 04 finish - Matt finish |
| Controller Type | Specially design Passbox interlock controller |
| Porosity | N.A. |
| Noise Level | N.A. |
| Velocity | Available in Dynamic Passbox |
| Grade | SS 304 |
| Model Name/Number | SPB & DPB |
| Display Type | LCD |
| Number Of Door | 2 OR 3 DOOR AS PER REQUIREMENT. |
| Is It Lockable | Lockable |
| Power Source | 230 V OR 440 VOLT |
| I Deal In | New Only |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Type | Vertical |
| Usage/Application | Industrial |
| Model Name/Number | HMG Laminar Air Flow |
| Size | customize |
| Material | Stainless Steel |
Laminar airflow (LAF) is a controlled and sterile air flow system used in various industries, particularly in healthcare and research settings. It is designed to create an environment with a consistent, unidirectional flow of filtered air to minimize the risk of contamination, maintain sterility, and protect sensitive processes or products. Here are some key points about laminar airflow:
Principle of Laminar Flow: Laminar airflow operates on the principle of creating a continuous and parallel stream of air moving in a single direction, typically from the top of the work area to the bottom (vertical laminar flow) or horizontally across the workspace (horizontal laminar flow). This ensures that airborne contaminants are pushed away and not allowed to settle in the critical zone.
Applications:
Types of Laminar Flow:
Filtration: Laminar airflow systems use HEPA (High-Efficiency Particulate Air) or ULPA (Ultra-Low Penetration Air) filters to remove airborne particles and microorganisms. These filters are highly efficient at trapping particles as small as 0.3 microns.
Maintenance: Regular maintenance is crucial to ensure the effectiveness of laminar airflow systems. Filters need to be replaced or cleaned, and airflow patterns should be checked to confirm they remain uniform.
Personal Protective Equipment (PPE): In laminar flow environments, operators often wear appropriate PPE, such as gloves, gowns, and masks, to prevent contamination from their side.
Validation: Laminar airflow systems are often subject to validation and certification to ensure they meet industry standards for cleanliness and airflow control.
Limitations: Laminar airflow is effective in controlling particulate contamination but may not be suitable for controlling chemical or biological contaminants. It is essential to consider the specific requirements of the application when selecting an airflow system.
Laminar airflow plays a critical role in maintaining aseptic conditions and ensuring product quality and safety in various industries that require a controlled environment.
Product Details:
| Material | Stainless Steel |
| Brand | HMG |
| Power Source | Electric |
| Phase | Single Phase |
| Voltage | 220 VAC |
| Frequency | 50 Hz |
Product Details:
| Door Finishing | Polished |
| Height | Standard |
| Noise | Standard |
| Color | Grey |
| Customisation | Customised |
| Brand | HMG India |
| Material | SS |
High Efficiency Particulate Air (HEPA) filters removes 99.97 % of particles greater than 0.3 micron in diameter from air / gas, whereas Ultra Low Penetration Air (ULPA) filters are rated for 99.997 % efficiency for particles down to 0.12 micron.
These are designed to remove particles down to 3, 5 and 10 microns in diameter from air / gas streams with better than 95 % efficiency when tested as per British Standard 2831 using Test Dust No. 11.
For mixing, weighing & dispensing of powder. The reverse flow scavenging pre-filter at the work level ensures that aerosolized particles are picked up at the source without allowing dispersing into the area.
A wide range (150 to 2000 CFM) of HEPA filter modules for use as duct connected clean air feed systems, pressurizing units & for supplying cooling air to Hot Air Sterilizers.
Complies with the guidelines & specifications laid down by British Standard 5726-for Class II Biological Safety / Cabinets. Applications include isolation & identification of plant / human pathogens, work in virology, tissue culture, sterility testing & recombinant DNA research. This biohazard cabinet offers operator protection from low to moderate risk work environment for the procedure. The cabinet is kept under negative pressure with partial quantity of recirculated air exhausted through a HEPA filter. External exhausted from the laboratory.
Pass Boxes with mechanically interlocked glass doors & UV light. Due to continue R & D model and specifications may change.
Product Details:
| Brand | HMG India |
| Usage/Application | Laboratory |
| Material | SS |
| Air Flow | Standard |
| Model Name/Number | Standard |
| Size | Standard |
| Condition | New |
Product Details:
| Voltage (V) | 230 |
| Material | Stainless Steel |
| Automatic Grade | Automatic |
| Brand | HMG India |
| Voltage Hz | 50 |
| Country of Origin | Made in India |